Made in China, supplied for global cable projects jixing88366@gmail.com WhatsApp: +86 18519748366 Phone: +86 18519748366

Cable Knowledge

Copper Cable or Aluminum Cable: Which Should I Buy?

Neither metal is the better choice in every case. Copper and aluminium (aluminum in US usage) conductors can both be suitable when the cable, the terminals and the installation are designed for the conductor material. The right choice comes from comparing the complete installed system, not the metal price per kilogram alone.

How do copper and aluminium conductors compare electrically?

Copper has higher conductivity than aluminium. For comparable resistance and current duty, a copper conductor is generally smaller than an aluminium conductor. The exact equivalence must be checked against the cable standard and a design calculation, not assumed from a general rule.

Resistance per kilometre drives voltage drop and losses. As a reference point, plain copper conductors in classes 1 and 2 have a maximum DC resistance at 20 °C of 1.15 Ω/km at 16 mm², according to IEC 60228. An aluminium conductor of the same size has higher resistance, which is why it usually needs a larger cross-section for the same duty.

Voltage drop limits come from the installation rules, not from the conductor material. IEC 60364-5-52 Annex G (informative) gives 3 % for lighting and 5 % for other uses on an installation supplied directly from a public low-voltage network, and 6 % and 8 % for a private low-voltage supply. National rules may differ, so check the rule that applies to your project.

Does the conductor material change the short-circuit check?

Yes. The adiabatic check uses S = I × √t / k, where S is the cross-section in mm², I is the fault current in A and t is the time in seconds. The k value depends on the conductor and insulation: 115 for copper with PVC, 143 for copper with XLPE, 76 for aluminium with PVC and 94 for aluminium with XLPE (IEC 60364-5-54 and IEC 60364-4-43). Because the aluminium k values are lower, the same fault needs a larger cross-section.

Worked example: a 10 kA fault cleared in 0.4 s on copper with PVC insulation gives S = 10,000 × √0.4 / 115 ≈ 55 mm², so the next standard size is 70 mm². The check is valid for faults up to about 5 s. For fast fuses and breakers, use the let-through I²t value from the manufacturer instead.

How do weight and size affect handling and installation?

Aluminium is much lighter than copper. Based on material density, copper conductor weighs about 8.89 kg per km for each mm² of cross-section, and aluminium about 2.70 kg per km for each mm². The lower weight can reduce handling effort and may simplify long runs.

The larger diameter of an aluminium cable affects conduit fill, bending radius, tray capacity and terminations. Copper is more compact and is often preferred where space is limited. The minimum bending radius depends on the cable construction and standard edition, so take the value from the manufacturer's datasheet rather than from a general rule.

How do copper and aluminium compare side by side?

The table summarises the main differences. Use it as a starting point for the specification, then confirm each row against the cable datasheet and the equipment maker's instructions.

FactorCopperAluminium
ConductivityHigher; a smaller conductor gives comparable resistanceLower; usually needs a larger cross-section
Density (kg per km per mm²)About 8.89 (material density)About 2.70 (material density)
Size and spaceCompact; suits limited tray or conduit spaceLarger diameter; check conduit fill, bend space and trays
Short-circuit k (PVC / XLPE)115 / 143 (IEC 60364-5-54, IEC 60364-4-43)76 / 94 (IEC 60364-5-54, IEC 60364-4-43)
TerminationsFamiliar practice; use lugs approved for copperUse lugs and terminals approved for aluminium, with oxide control

Density values are material properties used for weight estimates, not cable masses. The k values apply only to the adiabatic short-circuit check. Confirm terminal approval against the equipment instructions.

What should be checked at the connections?

Use lugs and terminals identified for the conductor material and size. Surface preparation, oxide control, tightening method and inspection should follow the equipment and connector instructions. Mixed-metal interfaces need suitable approved hardware, not improvised joints.

  • Check equipment terminals for the conductor material.
  • Include connector and oxide-control requirements in the specification.
  • Do not substitute at equal cross-section without a calculation.

How should the commercial comparison be made?

Compare cable cost, supports, tray size, pulling effort, terminations, losses and maintenance. A lower initial cable price may not produce the lowest installed or lifetime cost. If aluminium requires a larger cable, verify that switchgear lugs, glands, bend space and tray capacity still work with the new size.

Metal prices change over time and affect quotations, so ask suppliers to state the price basis clearly. The guide on copper price and cable quotation explains how to compare quotes on the same basis.

Equal cross-section does not mean equal performance. The useful comparison includes cable losses and termination labour, not only the conductor purchase price.

What to confirm before ordering

  1. Required ampacity and voltage drop for the actual load and cable route.
  2. Available raceway, tray and termination space.
  3. Approved lugs and equipment terminals for the chosen conductor material and size.
  4. Cable route, pulling method and bend space.
  5. Material price and lifetime losses, not only the cable purchase price.
  6. Project specification restrictions on conductor material.
  7. Written design approval before any change of conductor material or size.

Frequently asked questions

Is aluminium cable as good as copper cable?

Both can be suitable when the cable, terminals and installation are designed for the conductor material. Aluminium usually needs a larger cross-section than copper for a similar resistance, so the two are not interchangeable at the same size.

Can I replace copper cable with aluminium of the same cross-section?

Not without a design calculation and approval. The aluminium conductor has higher resistance, and the glands, lugs and equipment terminals may not be approved for it.

Is aluminium cable lighter than copper?

Yes. Aluminium has a material density of 2.70 g/cm³ compared with 8.89 g/cm³ for copper, so it weighs less per kilometre for each square millimetre of conductor.

Which k values apply to the short-circuit check?

In the adiabatic formula, use 115 for copper with PVC and 143 for copper with XLPE, and 76 for aluminium with PVC and 94 for aluminium with XLPE (IEC 60364-5-54 and IEC 60364-4-43). For fast fuses and breakers, use the manufacturer's let-through I²t instead.

Do aluminium conductors need special terminations?

Yes. Use lugs and terminals identified for aluminium conductor material and size, and follow the connector instructions for surface preparation, oxide control and tightening.

Is a lower cable price always the cheaper option?

Not necessarily. Installed cost includes supports, tray size, pulling effort, terminations, losses and maintenance, so compare the complete system.

References

Related cable products

Continue reading

Need a project quotation?

Send the cable model, voltage, conductor size, quantity, installation conditions and destination by WhatsApp or email.

Discuss on WhatsApp
WhatsApp